Sensor:
4096P CMOS GigE CMOS Line Scan Camera
Line Rate:
Base: 20 kHz (RGB 8)
Medium: 40 kHz (RGB 8)
Shutter Mode:
Off/ Once/ Continuous exposure mode; supports fixed exposure time
Gain:
Supports 1x /2x /4x
Exposure Time:
2 µs to 10 ms
Data Interface:
CameraLink, USB (only for firmware upgrade)
General Purpose I/O:
12-pin Hirose connector provides power and I/O: differential input x 2 (Line 0, Line 3), differential output x 2 (Line 1, Line4); CameraLink interface provides I/O (CC1/CC2/CC3/CC4)
Power Supply:
<4 W @12 VDC under heating mode, Voltage 12~24V
Lens Interface:
M42 × 1.0, optical back focal length 12mm (0.5"), applicable to F-mount, C-mount and lens of other types via adapter ring
Dimensions:
62 mm x 62 mm x 38 mm
Software:
MVS and the frame grabber software meeting with GenlCam standard
Operating System:
Windows XP/7/10 32/64 bit
Compliance:
CameraLink V1.2 protocol, GenICam standard
Certification:
CE, FCC, RoHS, KC